Each platform unit shall be installed so that
Web1) "Each scaffold and scaffold component must support its weight and _____ the maximum intended load applied to it." _____ p) 60: 2) "Each platform unit shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than _____ wide." Web(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space …
Each platform unit shall be installed so that
Did you know?
Webpermanent sign shall be installed on the switch enclosure or immediately adjacent to open ... (6 ft 7 in.) above the floor or working platform. Exception No. 1: On busway installations, fused switches and circuit breakers shall be permitted to be located at the same level as the busway. ... shall be installed so as to completely cover the ... WebEach platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is …
Web505.3 Equipment Platforms. Equipment platforms in buildings shall not be considered as a portion of the floor below. Such equipment platforms shall not contribute to either the … Webequivalent means, shall extend over the centerline of its support at least 6 inches. 1926.451(b) – Scaffold Platform Construction (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (i) Each platform unit shall be installed so that the space
WebDec 27, 2002 · (3) Dwelling Unit(s). At a dwelling unit, one 15A or 20A, 125V receptacle shall be located not less than 10 ft and not more than 20 ft from the water. This receptacle shall be located not more than 6 ft 6 in. above the floor, platform, or grade level serving the pool, outdoor spa or hot tub. WebEach platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the …
WebPlatform units could include scaffold-grade wooden planks, approved composite or metal fabricated planks, a fabricated deck, or a fabricated platform; • Each platform unit shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch wide. One exception to this rule is
WebMar 2, 2010 · Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and … incorporated company kısaltmasıWebPlatform units could include scaffold-grade wooden planks, approved composite or metal fabricated planks, a fabricated deck, or a fabricated platform; • Each platform unit … inciting incident of oedipus the kingWebAn application can be called a platform if it is a host to other programs. For example, Web browsers accept third-party plug-ins, and the browser becomes a platform to interface … inciting incident of the story of an hourWeb(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … inciting incident of masque of the red deathWebbuilding. As each level of brick or concrete block is put in place, the scaffold is cranked up to the next level. When the work is done at the top of the wall, then the scaffold is cranked back down to the ground and disassembled. Gilbane witnesses testified this scaffold had been on the job site for months. TE 114. inciting incident pdfWeb3314.5.1 Platform Spacing. Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between … inciting incident of one of us is lyingWebEach platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space … Occupational Safety & Health Administration. 200 Constitution Ave … inciting incident of the hunger games